Cic edizioni internazionali
Oral Implantology

FLAPLESS TRANSCRESTALMAXILLARY SINUS FLOOR ELEVATION: COMPUTER GUIDED IMPLANT SURGERY COMBINED WITH EXPANDING-CONDENSING OSTEOTOMES PROTOCOL

Case report, 4 - 9
Tag this article
Abstract
Full text PDF
English version
Flapless Transcrestal Maxillary Sinus Floor Elevation: computer guided implant surgery combined with expanding-condensing osteotomes protocol.
Purpose. A novel technique for transcrestal guided sinus lift elevation (TGSL), is described underlining the step by step surgical protocol.
Materials and methods. TGSL modified osteotome technique was planned by the NobelProcera® Software Planning Programm (Nobel Guide, Nobel Biocare AB) and performed by stereolitographic template. The depth of the planned osteotomy was determined precisely via crosssectional images of the elevation site to facilitate puncture of the bony sinus floor without risk of perforation of the adherent sinus membrane. A customized drilling-osteotome protocol is used to raise the Schneiderian membrane to the final implant length.
Results. The sinus membrane is successfully elevated in all sites without any iatrogenic perforation.
Conclusions. The TGSL modified osteotome technique may provide a new option for minimally invasive transcrestal sinus surgery and may represent a safe method to increase bone volume in the atrophic posterior maxilla. The results of the present study would suggest that this new surgical technique may reduce patient morbidity and extend the indications for transcrestal maxillary sinus floor elevation.

Verisione italiana
Il rialzo del seno mascellare per via transcrestale guidata con l'ausilio della chirurgia computer guidata e degli osteotomi.
Finalità. Viene descritto il protocollo chirurgico step by step di una nuova tecnica per l'elevazione del seno mascellare (TGSL). l'ausilio del software NobelClinician (NobelBiocare AB) e realizzata con la dima stereolitografica prodotta dalla pianificazione computerizzata.La profondità dell'osteotomia nel sito di elevazione del seno viene valutata sulle sezioni cross e sulle ricostruzioni 3D per facilitare la frattura controllata del pavimento del seno eliminando il rischio di perforazione della membrana. Una sequenza individualizzata di osteotomi è utilizzata per sollevare in modo atraumatico la membrana di Schneider.
Risultati. La membrana sinusale è stata sollevata con successo in tutti i siti trattati e nessuna perforazione iatrogena si è verificata.
Conclusioni. La tecnica TGSL rappresenta una nuova opzione procedurale mini-invasiva per l'elevazione transcrestale controllata del seno e può rappresentare una metodica a ridotta morbidità postoperatoria per incrementare il volume osseo nel mascellare atrofico posteriore.

Vol. X (No. 4) 2017 October - December

  1. IMPLANT-ABUTMENT CONNECTIONS ON SINGLE CROWNS: A SYSTEMATIC REVIEW
    Ceruso F.M., Barnaba P., Mazzoleni S., Ottria L., Gargari M., Zucon A., Bruno G., Di Fiore A.
    doi: 10.11138/orl/2017.10.4.349
  2. DENTAL UNIT WASTEWATER, A CURRENT ENVIRONMENTAL PROBLEM: A SISTEMATIC REVIEW
    Cataldi M.E., Al Rakayan S., Arcuri C., Arcuri C., Condò R.
    doi: 10.11138/orl/2017.10.4.354
  3. IN VITRO EVALUATION OF THE POST-SPACE DEPTH READING WITH AN INTRAORAL SCANNER (IOS) COMPARED TO A TRADITIONAL SILICON IMPRESSION
    Pinto A., Arcuri L., Carosi P., Nardi R., Libonati A., Ottria L., Campanella V.
    doi: 10.11138/orl/2017.10.4.360
  4. STRESS DISTRIBUTION OF VARIOUS DESIGNS OF PROSTHESES ON SHORT IMPLANTS OR STANDARD IMPLANTS IN POSTERIOR MAXILLA: A THREE DIMENSIONAL FINITE ELEMENT ANALYSIS
    Jomjunyong K., Rungsiyakull P., Rungsiyakull C., Aunmeungtong W., Chantaramungkorn M., Khongkunthian P.
    doi: 10.11138/orl/2017.10.4.369
  5. EFFECTIVENESS OF COMPUTER-ASSISTED ANESTHETIC DELIVERY SYSTEM (STA™) IN DENTAL IMPLANT SURGERY: A PROSPECTIVE STUDY
    Grassi F.R., Rapone B., Scarano Catanzaro F., Corsalini M., Kalemaj Z.
    doi: 10.11138/orl/2017.10.4.381
  6. IDENTIFICATION OF ORAL RISK FACTORS FOR CHRONIC GRAFT VERSUS HOST DISEASE IN HAEMATOLOGICAL PATIENTS WHO UNDERWENT ALLOGENEIC HAEMATOPOIETIC STEM CELL TRANSPLANTATION
    Picardi A., Miranda M., Liciani F., Paterno G., Arcese W., Bollero P.
    doi: 10.11138/orl/2017.10.4.390
  7. THERAPEUTIC EFFICIENCY OF PLATELET GEL FOR THE TREATMENT OF ORAL ULCERS RELATED TO CHRONIC GRAFT VERSUS HOST DISEASE AFTER ALLOGENEIC HAEMATOPOIETIC STEM CELL TRANSPLANTATION
    Picardi A., Ferraro A.S., Miranda M., Meconi F., Lanti A., Adorno G., Arcese W., Bollero P.
    doi: 10.11138/orl/2017.10.4.398
  8. LOW-LEVEL LASER THERAPY IN THE TREATMENT OF MUSCLE-SKELET PAIN IN PATIENTS AFFECTED BY TEMPOROMANDIBULAR DISORDERS
    Basili M., Barlattani jr. A., Venditti A., Bollero P.
    doi: 10.11138/orl/2017.10.4.406
  9. EFFECTS OF THE APPLICATION OF HIGH-PRESSURE OXYGEN ON THE TREATMENT OF PERIODONTAL DISEASE IN DIABETIC PATIENTS
    Sabatini S., Ricci M., Candotto V., Lauritano D., Nardi G.M.
    doi: 10.11138/orl/2017.10.4.412
  10. CORRELATION BETWEEN CORONAL AND APICAL ARCH FORM AND DEGREE OF DIVERGENCE: A VOLUMETRIC COMPUTED TOMOGRAPHY ANALYSIS
    Lombardo L., Veronesi F., Candotto V., Nardone M., Siciliani G.
    doi: 10.11138/orl/2017.10.4.424
  11. CEMENT LAYER THICKNESS AND SHEAR STRESS RESISTANCE IN CYLINDRICAL DOWEL SPACES: PULL-OUT TEST
    Andreasi Bassi M., Lauritano D., Brizzi M., Andrisani C., Lico S., Candotto V.
    doi: 10.11138/orl/2017.10.4.439
  12. UNICYSTIC AMELOBLASTOMA: REHABILITATION WITH CHIN GRAFT HARVESTED AND IMPLANT-SUPPORTED FIXED PROSTHESIS
    Sanz-Alonso J., Martinez-Rodriguez N., Martin-Ares M., Barona-Dorado C., Cortés Breton-Brinkmann J., Martinez-Gonazales J.M.
    doi: 10.11138/orl/2017.10.4.448
  13. POSITIONING OF A CONTEXTUAL IMPLANT ALONG WITH A SINUS LIFT ANCHORED WITH A BLOCK OF HETEROLOGOUS BONE
    Secondo F., Grottoli C.F., Zollino I., Perale G., Lauritano D.
    doi: 10.11138/orl/2017.10.4.457
  14. CLINICAL AND HISTOMORPHOMETRIC OUTCOME IN FUTURE SITE DEVELOPMENT PERFORMED WITH A NANO-HYDROXYAPATITE THROUGH HYDRAULIC SINUS LIFT TECHNIQUE
    Andreasi Bassi M., Lopez M.A., Confalone L., Lauritano D., Candotto V.
    doi: 10.11138/orl/2017.10.4.468
  15. “ALL ON SHORT” PROSTHETIC-IMPLANT SUPPORTED REHABILITATIONS
    Falisi G., Bernardi S., Rastelli C., Pietrapaoli D., De Angelis F., Frascaria M., Di Paolo C.
    doi: 10.11138/orl/2017.10.4.477
  16. BONE REGENERATION IN AESTHETIC AREAS USING TITANIUM MICROMESH. THREE CASE REPORTS
    Scarano A., Assenza B., Di Cerbo A., Candotto V., Santos De Oliveira P., Lorusso F.
    doi: 10.11138/orl/2017.10.4.488
  17. AN UNUSUAL, DECEPTIVE DELAYED OF PROFUSE HAEMORRHAGE AFTER MANDIBULAR IMPLANT DENTISTRY: RISK PLANNING AND MEDICO-LEGAL INSTRUCTION
    Gaudio R.M., El Haddad G., El Haddad G., Lauritano D., Carinci F.
    doi: 10.11138/orl/2017.10.4.495
  18. POLYSONOGRAPHICAL EVALUATION IN A CASE OF MODERATE OSAS TREATED WITH MANDIBULAR ADVANCEMENT DEVICE
    Venditti A., Basili M., Ragazzoni F.M., Barlattani jr. A., Bollero P.
    doi: 10.11138/orl/2017.10.4.502
Last Viewed articles: la lista degli ultimi x visitati.
  1. FLAPLESS TRANSCRESTALMAXILLARY SINUS FLOOR ELEVATION: COMPUTER GUIDED IMPLANT SURGERY COMBINED WITH EXPANDING-CONDENSING OSTEOTOMES PROTOCOL
    Pozzi A., De Vico G., Sannino G., Spinelli D., Schiavetti R., Ottria L., Barlattani A.
credits