Cic edizioni internazionali
Oral Implantology

POSITIONING OF A CONTEXTUAL IMPLANT ALONG WITH A SINUS LIFT ANCHORED WITH A BLOCK OF HETEROLOGOUS BONE

Original research, 457 - 467
doi: 10.11138/orl/2017.10.4.457
Tag this article
Abstract
Full text PDF
During a sinus lift procedure the main requirement in order to position an implant is to have a maxillary sinus floor cortical bone thick enough to guarantee a primary stability in the implant inserted. In this way, the healing process is facilitated and osseointegration of the titanium surface may occur simultaneously, thus reducing the waiting time for the engraftment of the implant into the body. Unfortunately, these conditions are not always present. Hence, the need of developing an alternative approach that could simultaneously allow to perform sinus floor elevation along with an implant placement.
Here we present the case of a 62-year-old patient that requires implant-prosthetic rehabilitation from 1.2 to 1.6 at diagnosis.
In this study, we reported a novel application derived from the use of a heterologous bone scaffold (SmartBone@) in a sinus lift procedure. We showed the successful implant along with sinus lift with SmartBone@, both at the time of the surgery and after follow-up of the patient at 10 months from the implant. The possibility to perform simultaneously the contextual implant along with sinus lift dramatically reduced the waiting time for the patient of minimum 5-6 months required for osseointegration of the grafted biomaterials, before performing the implant procedure. This surgery represents an advance both in terms of medical technique and as life-benefit for the patient.

Vol. X (No. 4) 2017 October - December

  1. IMPLANT-ABUTMENT CONNECTIONS ON SINGLE CROWNS: A SYSTEMATIC REVIEW
    Ceruso F.M., Barnaba P., Mazzoleni S., Ottria L., Gargari M., Zucon A., Bruno G., Di Fiore A.
    doi: 10.11138/orl/2017.10.4.349
  2. DENTAL UNIT WASTEWATER, A CURRENT ENVIRONMENTAL PROBLEM: A SISTEMATIC REVIEW
    Cataldi M.E., Al Rakayan S., Arcuri C., Arcuri C., Condò R.
    doi: 10.11138/orl/2017.10.4.354
  3. IN VITRO EVALUATION OF THE POST-SPACE DEPTH READING WITH AN INTRAORAL SCANNER (IOS) COMPARED TO A TRADITIONAL SILICON IMPRESSION
    Pinto A., Arcuri L., Carosi P., Nardi R., Libonati A., Ottria L., Campanella V.
    doi: 10.11138/orl/2017.10.4.360
  4. STRESS DISTRIBUTION OF VARIOUS DESIGNS OF PROSTHESES ON SHORT IMPLANTS OR STANDARD IMPLANTS IN POSTERIOR MAXILLA: A THREE DIMENSIONAL FINITE ELEMENT ANALYSIS
    Jomjunyong K., Rungsiyakull P., Rungsiyakull C., Aunmeungtong W., Chantaramungkorn M., Khongkunthian P.
    doi: 10.11138/orl/2017.10.4.369
  5. EFFECTIVENESS OF COMPUTER-ASSISTED ANESTHETIC DELIVERY SYSTEM (STA™) IN DENTAL IMPLANT SURGERY: A PROSPECTIVE STUDY
    Grassi F.R., Rapone B., Scarano Catanzaro F., Corsalini M., Kalemaj Z.
    doi: 10.11138/orl/2017.10.4.381
  6. IDENTIFICATION OF ORAL RISK FACTORS FOR CHRONIC GRAFT VERSUS HOST DISEASE IN HAEMATOLOGICAL PATIENTS WHO UNDERWENT ALLOGENEIC HAEMATOPOIETIC STEM CELL TRANSPLANTATION
    Picardi A., Miranda M., Liciani F., Paterno G., Arcese W., Bollero P.
    doi: 10.11138/orl/2017.10.4.390
  7. THERAPEUTIC EFFICIENCY OF PLATELET GEL FOR THE TREATMENT OF ORAL ULCERS RELATED TO CHRONIC GRAFT VERSUS HOST DISEASE AFTER ALLOGENEIC HAEMATOPOIETIC STEM CELL TRANSPLANTATION
    Picardi A., Ferraro A.S., Miranda M., Meconi F., Lanti A., Adorno G., Arcese W., Bollero P.
    doi: 10.11138/orl/2017.10.4.398
  8. LOW-LEVEL LASER THERAPY IN THE TREATMENT OF MUSCLE-SKELET PAIN IN PATIENTS AFFECTED BY TEMPOROMANDIBULAR DISORDERS
    Basili M., Barlattani jr. A., Venditti A., Bollero P.
    doi: 10.11138/orl/2017.10.4.406
  9. EFFECTS OF THE APPLICATION OF HIGH-PRESSURE OXYGEN ON THE TREATMENT OF PERIODONTAL DISEASE IN DIABETIC PATIENTS
    Sabatini S., Ricci M., Candotto V., Lauritano D., Nardi G.M.
    doi: 10.11138/orl/2017.10.4.412
  10. CORRELATION BETWEEN CORONAL AND APICAL ARCH FORM AND DEGREE OF DIVERGENCE: A VOLUMETRIC COMPUTED TOMOGRAPHY ANALYSIS
    Lombardo L., Veronesi F., Candotto V., Nardone M., Siciliani G.
    doi: 10.11138/orl/2017.10.4.424
  11. CEMENT LAYER THICKNESS AND SHEAR STRESS RESISTANCE IN CYLINDRICAL DOWEL SPACES: PULL-OUT TEST
    Andreasi Bassi M., Lauritano D., Brizzi M., Andrisani C., Lico S., Candotto V.
    doi: 10.11138/orl/2017.10.4.439
  12. UNICYSTIC AMELOBLASTOMA: REHABILITATION WITH CHIN GRAFT HARVESTED AND IMPLANT-SUPPORTED FIXED PROSTHESIS
    Sanz-Alonso J., Martinez-Rodriguez N., Martin-Ares M., Barona-Dorado C., Cortés Breton-Brinkmann J., Martinez-Gonazales J.M.
    doi: 10.11138/orl/2017.10.4.448
  13. POSITIONING OF A CONTEXTUAL IMPLANT ALONG WITH A SINUS LIFT ANCHORED WITH A BLOCK OF HETEROLOGOUS BONE
    Secondo F., Grottoli C.F., Zollino I., Perale G., Lauritano D.
    doi: 10.11138/orl/2017.10.4.457
  14. CLINICAL AND HISTOMORPHOMETRIC OUTCOME IN FUTURE SITE DEVELOPMENT PERFORMED WITH A NANO-HYDROXYAPATITE THROUGH HYDRAULIC SINUS LIFT TECHNIQUE
    Andreasi Bassi M., Lopez M.A., Confalone L., Lauritano D., Candotto V.
    doi: 10.11138/orl/2017.10.4.468
  15. “ALL ON SHORT” PROSTHETIC-IMPLANT SUPPORTED REHABILITATIONS
    Falisi G., Bernardi S., Rastelli C., Pietrapaoli D., De Angelis F., Frascaria M., Di Paolo C.
    doi: 10.11138/orl/2017.10.4.477
  16. BONE REGENERATION IN AESTHETIC AREAS USING TITANIUM MICROMESH. THREE CASE REPORTS
    Scarano A., Assenza B., Di Cerbo A., Candotto V., Santos De Oliveira P., Lorusso F.
    doi: 10.11138/orl/2017.10.4.488
  17. AN UNUSUAL, DECEPTIVE DELAYED OF PROFUSE HAEMORRHAGE AFTER MANDIBULAR IMPLANT DENTISTRY: RISK PLANNING AND MEDICO-LEGAL INSTRUCTION
    Gaudio R.M., El Haddad G., El Haddad G., Lauritano D., Carinci F.
    doi: 10.11138/orl/2017.10.4.495
  18. POLYSONOGRAPHICAL EVALUATION IN A CASE OF MODERATE OSAS TREATED WITH MANDIBULAR ADVANCEMENT DEVICE
    Venditti A., Basili M., Ragazzoni F.M., Barlattani jr. A., Bollero P.
    doi: 10.11138/orl/2017.10.4.502
Last Viewed articles: la lista degli ultimi x visitati.
  1. POSITIONING OF A CONTEXTUAL IMPLANT ALONG WITH A SINUS LIFT ANCHORED WITH A BLOCK OF HETEROLOGOUS BONE
    Secondo F., Grottoli C.F., Zollino I., Perale G., Lauritano D.
    doi: 10.11138/orl/2017.10.4.457
credits