Cic edizioni internazionali
Oral Implantology

EFFECTS OF THE APPLICATION OF HIGH-PRESSURE OXYGEN ON THE TREATMENT OF PERIODONTAL DISEASE IN DIABETIC PATIENTS

Original research, 412 - 423
doi: 10.11138/orl/2017.10.4.412
Tag this article
Abstract
Full text PDF
Purpose. In this study we wanted to observe the improvement in the healing of periodontal tissues in a group of diabetic patients treated with traditional methods compared to another group treated with the addition of oxygen.
The potential of oxygen has long been known in the field of plastic surgery, where it is used to treat burns and skin lesions.
Materials and methods. This study consists in a split mouth study which involved 30 patients. We carefully treated them with periodontal therapy using manual and mechanical instrumentation. Then, we applied oxygen in half mouth according to randomization list. Finally we checked up patients after some weeks.
Results. Our results highlight that all areas treated with oxygen application healed more rapidly and better than no treated areas.
Conclusions. All in all, we have demonstrated that oxygen can improve the outcome of non-surgical periodontal treatment in diabetic subjects.

Vol. X (No. 4) 2017 October - December

  1. IMPLANT-ABUTMENT CONNECTIONS ON SINGLE CROWNS: A SYSTEMATIC REVIEW
    Ceruso F.M., Barnaba P., Mazzoleni S., Ottria L., Gargari M., Zucon A., Bruno G., Di Fiore A.
    doi: 10.11138/orl/2017.10.4.349
  2. DENTAL UNIT WASTEWATER, A CURRENT ENVIRONMENTAL PROBLEM: A SISTEMATIC REVIEW
    Cataldi M.E., Al Rakayan S., Arcuri C., Arcuri C., Condò R.
    doi: 10.11138/orl/2017.10.4.354
  3. IN VITRO EVALUATION OF THE POST-SPACE DEPTH READING WITH AN INTRAORAL SCANNER (IOS) COMPARED TO A TRADITIONAL SILICON IMPRESSION
    Pinto A., Arcuri L., Carosi P., Nardi R., Libonati A., Ottria L., Campanella V.
    doi: 10.11138/orl/2017.10.4.360
  4. STRESS DISTRIBUTION OF VARIOUS DESIGNS OF PROSTHESES ON SHORT IMPLANTS OR STANDARD IMPLANTS IN POSTERIOR MAXILLA: A THREE DIMENSIONAL FINITE ELEMENT ANALYSIS
    Jomjunyong K., Rungsiyakull P., Rungsiyakull C., Aunmeungtong W., Chantaramungkorn M., Khongkunthian P.
    doi: 10.11138/orl/2017.10.4.369
  5. EFFECTIVENESS OF COMPUTER-ASSISTED ANESTHETIC DELIVERY SYSTEM (STA™) IN DENTAL IMPLANT SURGERY: A PROSPECTIVE STUDY
    Grassi F.R., Rapone B., Scarano Catanzaro F., Corsalini M., Kalemaj Z.
    doi: 10.11138/orl/2017.10.4.381
  6. IDENTIFICATION OF ORAL RISK FACTORS FOR CHRONIC GRAFT VERSUS HOST DISEASE IN HAEMATOLOGICAL PATIENTS WHO UNDERWENT ALLOGENEIC HAEMATOPOIETIC STEM CELL TRANSPLANTATION
    Picardi A., Miranda M., Liciani F., Paterno G., Arcese W., Bollero P.
    doi: 10.11138/orl/2017.10.4.390
  7. THERAPEUTIC EFFICIENCY OF PLATELET GEL FOR THE TREATMENT OF ORAL ULCERS RELATED TO CHRONIC GRAFT VERSUS HOST DISEASE AFTER ALLOGENEIC HAEMATOPOIETIC STEM CELL TRANSPLANTATION
    Picardi A., Ferraro A.S., Miranda M., Meconi F., Lanti A., Adorno G., Arcese W., Bollero P.
    doi: 10.11138/orl/2017.10.4.398
  8. LOW-LEVEL LASER THERAPY IN THE TREATMENT OF MUSCLE-SKELET PAIN IN PATIENTS AFFECTED BY TEMPOROMANDIBULAR DISORDERS
    Basili M., Barlattani jr. A., Venditti A., Bollero P.
    doi: 10.11138/orl/2017.10.4.406
  9. EFFECTS OF THE APPLICATION OF HIGH-PRESSURE OXYGEN ON THE TREATMENT OF PERIODONTAL DISEASE IN DIABETIC PATIENTS
    Sabatini S., Ricci M., Candotto V., Lauritano D., Nardi G.M.
    doi: 10.11138/orl/2017.10.4.412
  10. CORRELATION BETWEEN CORONAL AND APICAL ARCH FORM AND DEGREE OF DIVERGENCE: A VOLUMETRIC COMPUTED TOMOGRAPHY ANALYSIS
    Lombardo L., Veronesi F., Candotto V., Nardone M., Siciliani G.
    doi: 10.11138/orl/2017.10.4.424
  11. CEMENT LAYER THICKNESS AND SHEAR STRESS RESISTANCE IN CYLINDRICAL DOWEL SPACES: PULL-OUT TEST
    Andreasi Bassi M., Lauritano D., Brizzi M., Andrisani C., Lico S., Candotto V.
    doi: 10.11138/orl/2017.10.4.439
  12. UNICYSTIC AMELOBLASTOMA: REHABILITATION WITH CHIN GRAFT HARVESTED AND IMPLANT-SUPPORTED FIXED PROSTHESIS
    Sanz-Alonso J., Martinez-Rodriguez N., Martin-Ares M., Barona-Dorado C., Cortés Breton-Brinkmann J., Martinez-Gonazales J.M.
    doi: 10.11138/orl/2017.10.4.448
  13. POSITIONING OF A CONTEXTUAL IMPLANT ALONG WITH A SINUS LIFT ANCHORED WITH A BLOCK OF HETEROLOGOUS BONE
    Secondo F., Grottoli C.F., Zollino I., Perale G., Lauritano D.
    doi: 10.11138/orl/2017.10.4.457
  14. CLINICAL AND HISTOMORPHOMETRIC OUTCOME IN FUTURE SITE DEVELOPMENT PERFORMED WITH A NANO-HYDROXYAPATITE THROUGH HYDRAULIC SINUS LIFT TECHNIQUE
    Andreasi Bassi M., Lopez M.A., Confalone L., Lauritano D., Candotto V.
    doi: 10.11138/orl/2017.10.4.468
  15. “ALL ON SHORT” PROSTHETIC-IMPLANT SUPPORTED REHABILITATIONS
    Falisi G., Bernardi S., Rastelli C., Pietrapaoli D., De Angelis F., Frascaria M., Di Paolo C.
    doi: 10.11138/orl/2017.10.4.477
  16. BONE REGENERATION IN AESTHETIC AREAS USING TITANIUM MICROMESH. THREE CASE REPORTS
    Scarano A., Assenza B., Di Cerbo A., Candotto V., Santos De Oliveira P., Lorusso F.
    doi: 10.11138/orl/2017.10.4.488
  17. AN UNUSUAL, DECEPTIVE DELAYED OF PROFUSE HAEMORRHAGE AFTER MANDIBULAR IMPLANT DENTISTRY: RISK PLANNING AND MEDICO-LEGAL INSTRUCTION
    Gaudio R.M., El Haddad G., El Haddad G., Lauritano D., Carinci F.
    doi: 10.11138/orl/2017.10.4.495
  18. POLYSONOGRAPHICAL EVALUATION IN A CASE OF MODERATE OSAS TREATED WITH MANDIBULAR ADVANCEMENT DEVICE
    Venditti A., Basili M., Ragazzoni F.M., Barlattani jr. A., Bollero P.
    doi: 10.11138/orl/2017.10.4.502
Last Viewed articles: la lista degli ultimi x visitati.
  1. EFFECTS OF THE APPLICATION OF HIGH-PRESSURE OXYGEN ON THE TREATMENT OF PERIODONTAL DISEASE IN DIABETIC PATIENTS
    Sabatini S., Ricci M., Candotto V., Lauritano D., Nardi G.M.
    doi: 10.11138/orl/2017.10.4.412
credits