Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study

Original research, 202 - 212
doi: 10.11138/orl/2016.9.4.202
Tag this article
Abstract
Enhanced HTML Full text PDF
Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process.
Purpose. Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs.
Materials and methods. Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9x9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution.
Results. There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique
45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models.
Conclusions. Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models.
Clinical implications. Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force.

Vol. XII (No. 1) 2019 January-March

  1. INFERENTIAL ANALYSIS OF BIG DATA IN REAL-TIME: ONE GIANT LEAP FOR SPATIOTEMPORAL DIGITAL EPIDEMIOLOGY IN DENTISTRY
    Al-Imam A.
  2. POLY(ɛ-CAPROLACTONE) MEMBRANES COATED WITH POLY(4-STYRENESULFONIC ACID-CO-MALEIC ACID)-SODIUM SALT ENHANCE OSTEOGENIC PROPERTIES OF PRE-OSTEOBLASTS MC3T3-E1
    Angwarawong T., Kanjanamekanant K., Angwaravong O., Pavasant P.
  3. FRACTURE RESISTANCE OF MONOLITHIC ZIRCONIA CANTILEVERED FRAMEWORKS IN COMPLETE ARCH-PROSTHESES SUPPORTED BY TILTED OR PARALLEL IMPLANTS
    De Francesco M., Di Fiore A., Bruno G., Gargari M., Martelli M., Barnaba P., Marino M., Quercia A., Ceruso F.M.
  4. RARE CASE OF INVERTED IMPACTED CANINE IN INFRA-ORBITARY POSITION REQUIRING SURGICAL THERAPY
    Falisi G., Cutilli T., Rastelli E., Bernardi S., Continenza M.A., Vittorini Velasquez P., Severino M.
  5. VERTICAL AND HORIZONTAL BONE REGENERATION
    Ciulli E., Fabretti M., Casale F., Lanzuolo S., Gargari M.
  6. ORTHODONTIC EXTRUSION FOR PRE-IMPLANT SITE ENHANCEMENT IN A POSTERIOR AREA: AN INTERDISCIPLINARY CASE REPORT
    Giannetti L., Consolo U., Vecci F., Apponi R.
  7. PROGNOSIS OF SHORT IMPLANTS IN ORAL REHABILITATION: WHERE DO WE STAND TODAY?
    Rameh S., Menhall A., Younes R.
  8. FRACTURES OF CROWN, ROOT AND AVULSION OF PERMANENT TEETH: CASE REPORT OF COMPLEX TRAUMATIC DENTAL INJURIES
    Di Taranto V., Severino M., Agrestini C., Barlattani A.
  9. ECC FULL REHABILITATION WITH INDIRECT COMPOSITE RESTORATIONS: A CASE REPORT
    Gallusi G., Severino M., Cardelli P., Barlattani jr. A.
  10. DIRECT ADHESIVE REHABILITATION WITH DOUBLE INDEX TECHNIQUE: A CASE REPORT
    Libonati A., Severino M., Dolci A., Barlattani A.
Last Viewed articles: la lista degli ultimi x visitati.
  1. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study
    Aunmeungtong W., Khongkunthian P., Rungsiyakull P.
    doi: 10.11138/orl/2016.9.4.202