Cic edizioni internazionali
Oral Implantology

Friction in a hybrid system. An in vitro study

Research Article, 2 - 8
Tag this article
Abstract
Full text PDF
English version
Friction in a hybrid system. An in vitro study
Aim. The aim of this study was to compare the frictional force generated by self-ligating and conventional brackets coupled with stainless steel wires when conventional elastomeric or stainless steel ligatures were applied.
Method. Four types of brackets were selected for the study: one passive self-ligating bracket, two active self-ligating brackets, and one conventional bracket. For each type of bracket one molar tube and two upper premolars were used in combination with three different wires (0.016x0.022, 0.017x0.025 and 0.019x0.025 inch). Testing was performed with an Instron machine. Each bracket/wire combination was tested with conventional elastomeric and stainless steel ligatures. Tests performed with self-ligating brackets were carried out also without conventional ligatures. ANOVA with Tukey's post hoc tests were used to compare the results for the different bracket/wire/ligature assemblies.
Results. Active self-ligating bracket/0.017x0.025 inch or 0.019x0.025 inch/stainless steel ligature assemblies showed significantly higher values of frictional forces than conventional bracket for the same combinations. Passive self-ligating brackets showed significantly lower values of friction than conventional brackets for each wire/ligature assembly.
Conclusions. The use of stainless steel ligatures applied on active self-ligating brackets produced significantly higher level of frictional force than in combination with conventional brackets for 0.017x0.025 inch and 0.019x0.025 inch wires.

Versione italiana
Attrito in un sistema ibrido: uno studio in vitro.
Obiettivi. Scopo di questo lavoro è stato comparare la forza di attrito generata da brackets autoleganti e convenzionali utilizzati in combinazione con l’apposizione di legature convenzionali elastiche e metalliche.
Metodi. Per l’esecuzione dei test sono stati selezionati quattro modelli di brackets: un autolegante passivo, due brackets autoleganti interattivi ed un attacco convenzionale. Per ogni tipologia di bracket sono stati utilizzati un tubo molare e due attacchi premolari. Le prove sono state condotte con una Instron machine, tutti gli attacchi sono stati testati in combinazione con tre sezioni di archi ortodontici (0.016x0.022, 0.017x0.025 e 0.019x0.025 inch). Ogni combinazione arco-bracket è stata testata con legature elastiche e metalliche. Per l’analisi statistica dei dati è stato utilizzato il test ANOVA a tripla via e come Post-hoc test il test di Tukey.
Risultati. I brackets autoleganti attivi hanno evidenziato valori di resistenza allo scorrimento maggiori rispetto a quelli degli attacchi convenzionali se analizzati in combinazione con legature metalliche ed archi di sezione 0.017x0.025 e 0.019x0.025 inch. I brackets autoleganti passivi hanno prodotto valori di attrito inferiori rispetto agli attacchi standard.
Conclusioni. L’utilizzo di legature metalliche in combinazione con brackets autoleganti interattivi su archi 0.017x0.025 e 0.019x0.025 produce valori di attrito superiori rispetto agli attacchi convenzionali.

Vol. XII (No. 1) 2019 January-March

  1. INFERENTIAL ANALYSIS OF BIG DATA IN REAL-TIME: ONE GIANT LEAP FOR SPATIOTEMPORAL DIGITAL EPIDEMIOLOGY IN DENTISTRY
    Al-Imam A.
  2. POLY(ɛ-CAPROLACTONE) MEMBRANES COATED WITH POLY(4-STYRENESULFONIC ACID-CO-MALEIC ACID)-SODIUM SALT ENHANCE OSTEOGENIC PROPERTIES OF PRE-OSTEOBLASTS MC3T3-E1
    Angwarawong T., Kanjanamekanant K., Angwaravong O., Pavasant P.
  3. FRACTURE RESISTANCE OF MONOLITHIC ZIRCONIA CANTILEVERED FRAMEWORKS IN COMPLETE ARCH-PROSTHESES SUPPORTED BY TILTED OR PARALLEL IMPLANTS
    De Francesco M., Di Fiore A., Bruno G., Gargari M., Martelli M., Barnaba P., Marino M., Quercia A., Ceruso F.M.
  4. RARE CASE OF INVERTED IMPACTED CANINE IN INFRA-ORBITARY POSITION REQUIRING SURGICAL THERAPY
    Falisi G., Cutilli T., Rastelli E., Bernardi S., Continenza M.A., Vittorini Velasquez P., Severino M.
  5. VERTICAL AND HORIZONTAL BONE REGENERATION
    Ciulli E., Fabretti M., Casale F., Lanzuolo S., Gargari M.
  6. ORTHODONTIC EXTRUSION FOR PRE-IMPLANT SITE ENHANCEMENT IN A POSTERIOR AREA: AN INTERDISCIPLINARY CASE REPORT
    Giannetti L., Consolo U., Vecci F., Apponi R.
  7. PROGNOSIS OF SHORT IMPLANTS IN ORAL REHABILITATION: WHERE DO WE STAND TODAY?
    Rameh S., Menhall A., Younes R.
  8. FRACTURES OF CROWN, ROOT AND AVULSION OF PERMANENT TEETH: CASE REPORT OF COMPLEX TRAUMATIC DENTAL INJURIES
    Di Taranto V., Severino M., Agrestini C., Barlattani A.
  9. ECC FULL REHABILITATION WITH INDIRECT COMPOSITE RESTORATIONS: A CASE REPORT
    Gallusi G., Severino M., Cardelli P., Barlattani jr. A.
  10. DIRECT ADHESIVE REHABILITATION WITH DOUBLE INDEX TECHNIQUE: A CASE REPORT
    Libonati A., Severino M., Dolci A., Barlattani A.
Last Viewed articles: la lista degli ultimi x visitati.
  1. Friction in a hybrid system. An in vitro study
    Rozzi M., Mucedero M., Franchi L., Cozza P.
credits